 Many heating and cooling systems suffer from chronic problems.No matter whether they are small domestic systems or large commercial systems in hospitals or airports. Many heating and cooling systems suffer from chronic problems.No matter whether they are small domestic systems or large commercial systems in hospitals or airports.
-The most common problems ​are known to all installers and maintenance companies, like sticking thermostatic radiator valves, frequent pump failures, blocked valves, noisy boilers, leaks, increasing energy consumption,​ system pressure ​dropping ​and requiring frequent top-ups, black sludge and reddish-brown water.+Many of the symptoms ​are known to all installers and maintenance companies, like sticking thermostatic radiator valves, frequent pump failures, blocked valves, noisy boilers, leaks, increasing energy consumption, ​dropping ​system pressure and requiring frequent top-ups, black sludge and reddish-brown water.
 Often these problems are seen as normal and unavoidable. Left untreated they will inevitably lead to component and in the end even complete system failure. Power flushing and chemical treatment often fail to cure the problem ​ Often these problems are seen as normal and unavoidable. Left untreated they will inevitably lead to component and in the end even complete system failure. Power flushing and chemical treatment often fail to cure the problem ​
- and can even make the problem worse.+and frequently ​make the problem worse.
  
  
Line 376: Line 376:
   * Incorrect pump position   * Incorrect pump position
  
-===== Types of corrosin ​Monitors =====+===== Types of corrosion ​Monitors =====
  
 There are a number of ways that corrosion can be monitored either directly or indirectly. There are a number of ways that corrosion can be monitored either directly or indirectly.
Line 469: Line 469:
 Devices such as micro-bubble separators, pressure step degassers, automatic air vents etc. cannot prevent corrosion. The oxygen in the air bubbles reacts very quickly with the steel it comes into contact with.This happens faster than the separators can expell the air. If the expelled ´air´is analysed it is found to be mainly consisting of nitrogen. ​ Devices such as micro-bubble separators, pressure step degassers, automatic air vents etc. cannot prevent corrosion. The oxygen in the air bubbles reacts very quickly with the steel it comes into contact with.This happens faster than the separators can expell the air. If the expelled ´air´is analysed it is found to be mainly consisting of nitrogen. ​
  
-==== Chemical Water Treatment and Water Conditioning ====+==== Chemical Water Treatment and Water Conditioning==== 
 The condition of the fill and system water can have a marked effect on the corrosion potential. Water is a cheap and plentiful medium and is, therefore, the preferred liquid. Water isn't just water and water chemistry is very complex. It can be highly corrosive to steel and other metals if certain values such as pH and conductivity are unfavourable. ​   The condition of the fill and system water can have a marked effect on the corrosion potential. Water is a cheap and plentiful medium and is, therefore, the preferred liquid. Water isn't just water and water chemistry is very complex. It can be highly corrosive to steel and other metals if certain values such as pH and conductivity are unfavourable. ​  
 There are different methods of achieving the right water chemistry. The water can be either conditioned or chemically treated or both. There are different methods of achieving the right water chemistry. The water can be either conditioned or chemically treated or both.